Installation Manual Omnicell Model: 9101 FB Load Cell Only Some Models 51172 © 2007 by Fairbanks Scales, Inc.
Amendment Record Omnicell 9101 FB DOCUMENT 51172 Manufactured by Fairbanks Scales Inc.
Disclaimer Every effort has been made to provide complete and accurate information in this manual. However, although this manual may include a specifically identified warranty notice for the product, Fairbanks Scales makes no representations or warranties with respect to the contents of this manual, and reserves the right to make changes to this manual without notice when and as improvements are made.
Table of Contents SECTION 1: GENERAL INFORMATION .................................................................. 6 Description........................................................................................................................... 6 Features .......................................................................................................................................... 6 Applications...............................................................................................
Section 1: General Information DESCRIPTION Fairbanks’ Omnicell® 9101 FB Series is a single-ended beam weighing assembly. It is a cost-effective choice for low capacity, indoor, commercial and non-commercial weighing applications. Features • Low-to-medium weight range Omnicells® — 50 to 2,500 lb capacity models. • Stainless steel mounting hardware. • Low profile design. • Load Cell Types ─ Stainless Steel Load Cell — 50 to 250 lb capacity models.
Section 1: General Information Dimensions (In Inches) CAPACITY A B C D E F G H I J K L M TYPE 25–250 lbs 4 3.13 3 0.37 3.25 2.25 3.88 3.00 0.50 0.22 2.38 0.38 0.34 Y 500 lbs 6 3.88 4 1.00 4.00 3.00 5.50 4.13 0.50 0.25 3.38 0.56 0.47 Y 1,000 lbs 6 4.00 4 1.00 4.00 3.00 5.13 4.13 0.50 0.13 3.00 0.44 0.47 X 2,500 lbs 6 4.00 4 1.00 4.00 3.00 6.25 5.00 0.50 0.38 4.62 0.44 0.
Section 1: General Information SPECIFICATIONS Capacities 50, 75, 100, 150, 250, 500, 1,000 and 2,500 lbs. Mount Construction • Stainless steel Base Plate • Reinforced Neoprene Top Plate Full Scale Output (FSO) 3.0mV/v ± 0.25% Combined Error (FSO) ≤ 0.03% Non-Linearity (FSO) ≤ 0.03% Hysteresis (FSO) ≤ 0.02% Creep Error (20 min.) ≤ 0.
Section 2: Installation GENERAL SERVICE POLICIES Phases of Installation 1. Verifying the application. 2. Unpacking & equipment checkout. 3. Installation & adjustments. 4. Customer check-off and site readiness.. Conferring with Our Client • The lead tech must be prepared to recommend the arrangement of components which provide the most efficient layout, utilizing the equipment to the best possible advantage. • The warranty policy must be explained and reviewed with the customer.
Section 2: Installation Pre-Installation Checklist The following points should be checked and discussed with the Area Sales Manager and/or customer, if necessary, before the technician goes to the site and installs the equipment. 9 Check the customer's application to make certain it is within the capabilities and design parameters of the equipment. 9 If the installation process might disrupt normal business operations, tell the customer and ask that they make ample arrangements.
Section 2: Installation User’s Responsibilities 1. All electronic and mechanical calibrations and or adjustments required for making this equipment perform to accuracy and operational specifications are considered to be part of the installation. ─ They are included in the installation charge. ─ Only those charges which are incurred as a result of the equipment's inability to be adjusted or calibrated to performance specifications may be charged to warranty. 2.
Section 2: Installation INSTALLATION Basic Assembly Steps 1. Raise the vessel that is to be supported by the Omnicell® Assemblies. 2. Secure the Assembly by safely placing blocks under the vessel to the required height. 3. Place each Assembly onto a level surface under each support leg. 4. Set the Assemblies for the correct load cell orientation (as shown on the following page). 5. Insert the four (4) 5/16-18 bolts, and then fasten them loosely to the support leg for each assembly. 6.
Section 2: Installation Load Cell Placement Follow these guidelines for installing Omnicell® Load Cells. 1. The loading points of the modules should be as far from one another as the structure allows. 2. When installing the square and rectangle Omnicell units, line up the Base Plates of the Load Cells with each other, and align them evenly from the end and the sides of the units. 3.
Section 3: Parts Omnicell® 9101 FB Complete Units Part No. Description Each assembly includes all necessary Omnicell Unit parts. 27871 Omnicell, w/ Fabricated SS Mount, SS Load Cell 50 lb. Capacity 27872 Omnicell, w/ Fabricated SS Mount, SS Load Cell 75 lb. Capacity 27873 Omnicell, w/ Fabricated SS Mount, SS Load Cell 100 lb. Capacity 27874 Omnicell, w/ Fabricated SS Mount, SS Load Cell 150 lb. Capacity 27875 Omnicell, w/ Fabricated SS Mount, SS Load Cell 250 lb.
Section 3: Parts Rubber Mounts Fairbanks P/N Components 93640 Rubber Mount 52522, 9101 FB (50 – 150 lbs) 93641 Rubber Mount 52542, 9101 FB (250 lbs) 93642 Rubber Mount 52172, 9101 FB (500 – 1,000 lbs) 93643 Rubber Mount 52564-1, 9101 FB (2.500 lbs) Parts Not Supplied with Assembly Qty.
Section 3: Parts Assembly Units Without Load Cells Fairbanks P/N Diagram Letter 93644 Qty 1 Components 9101 FB Mounting Ass’y (50 - 150 lbs) Assembly includes the following parts (without a load cell). 93640 A 1 SS Base Plate B 1 Load Cell Shim Spacer * 1 Hex Nose Spacer C 1 Rubber Mount, 52522 * 1 * 1 Jam Nut, 3/8" - 16 E 2 Load Cell Mounting Bolt, 1/4-20 X 1.50" F 3 Lock Washer,1/4” Spring Ring 93645 1 Nose Bolt, 1/4-20 X .
Section 3: Parts Assembly Units Without Load Cells, Continued Fairbanks P/N Diagram Letter 93646 Qty. 1 Components 9101 FB Mounting Ass’y (500 & 1,000 lbs) Assembly includes the following parts (without a load cell). 93642 A 1 B 1 * 1 C 1 * 1 E 2 F 2 93647 1 SS Base Plate Rubber Mount, 52172 Spacer, load cell shim Nose Spacer Bolt, nose 1/2-20 X 2.0" Bolt, load cell mounting 1/2-13 X 2.
Appendix I: Omnicell Configurations Omnicell9101 FB Bending Beam design with capacities equal to or less than 250 pounds. Omnicell 9101 FB Sheer Beam design with capacities greater than 250 pounds.
Omnicell Manufactured by Fairbanks Scales, Inc. 821 Locust Street Kansas City, Missouri 64106 www.fairbanks.