Instruction Manual


6. If the problem still exists, replace the affected AXIS UNit. (Refer to Section 8.3.3)
7. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)
WARNING:
DO NOT CONNECT OR DISCONNECT CABLES OR OTHER SYSTEM
COMPONENTS WITH POWER APPLIED.
9.3.7 PARAMETER SET ABNORMAL
<ERROR DESCRIPTION>
Fastening presets are set-up incorrectly.
<CHECK ITEMS>
1. Verify that the MACHINE CONFIGURATION / SET SEQUENCE / SET PARAMETER
screens match the physical machine configuration.
2. Re-enter the data on the MACHINE CONFIGURATION / SET SEQUENCE / SET
PARAMETER screens (or reload the Preset files from the PRESET FILE UTILITY
screen).
3. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.
4. Confirm that the ISA Main Unit input power remains constantly within specifications:
200~230 VAC +/- 10%, 50/60 Hz, single phase.
5. Verify that the ISA Main Unit power cable is free from damage and is properly connected.
6. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)
9.3.8 SYSTEM CONFIG SET ABNORMAL
<ERROR DESCRIPTION>
The SYstem Configuration is set-up incorrectly.
<CHECK ITEMS>
1. Verify that the MACHINE CONFIGURATION / SET SEQUENCE / SET PARAMETER
screens match the physical machine configuration.
2. Re-enter the data on the MACHINE CONFIGURATION / SET SEQUENCE / SET
PARAMETER screens (or reload the Preset files from the PRESET FILE UTILITY
screen).
3. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.
4. Confirm that the ISA Main Unit input power remains constantly within specifications:
200~230 VAC +/- 10%, 50/60 Hz, single phase.
5. Verify that the ISA Main Unit power cable is free from damage and is properly connected.
6. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)
9.3.9 CONSOLE DUAL PORT RAM ABNORMAL
<ERROR DESCRIPTION>
Multi2 PCB DUAL PORT error between the Processor PCB and Multi2 PCB.
<CHECK ITEMS>
1. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.
Chapter 9: Troubleshooting