User Manual

enFORCE Operation Manual
PAGE 3 - 4
Chapter 3: System Description
3.2.2 DSP1500 Front Panel Condition Display LED’s
POWER LED (Yellow)
Lights when 180~242VAC input power is applied to
the controller.
BUSY LED (Orange)
Lights up when in cycle
Blinks when returning
Blinks when running in MANUAL
Lights up when powering on and initializing
SV. [SERVO] LED (Red)
Lights up when a servo amplifier fault condition
exists.
ABN. [ABNORMAL] LED (Red)
Lights up when an abnormal condition occurs
ACC. [ACCEPT] LED (Green)
Lights up when normal or within limits
REJ. [REJECT] LED (Red)
Lights up or blinks when exceeding judgment limit
Solid light: exceeding load control limits
Fast blink: exceeding distance control limits
Slow blink: exceeding load rate/time limits
BYPASS/RUN LED (Red)
Solid light when switch is in RUN position and not
receiving a BYPASS signal from an external source.
Blinking light when switch is in BYPASS position or
when a BYPASS signal from an external source is
received.
*Switch in BYPASS position overrides signal
from an external source.
M O T O R
A C 2 0 0 - 2 2 0 V
P L C
T / D
R S
4 8 5
R U N
B Y P A S S
S W1
C O N 1
P O WE R
B U S Y
S V.
A
B N .
A CC .
R EJ .
FEC
SAN3-24S
M O N .
R E S O L V E R