User Manual

enFORCE Operation Manual
PAGE 3 - 7
Chapter 3: System Description
3.3 Press Tool
Drawing Shown For Reference Only
A) MOTOR: Totally enclosed DC permanent magnet motor
Refer to Chapter 2 for available motor sizes
B) RESOLVER: Provides feedback for speed regulation to servo amplifier
Provides distance monitoring capability to press operation
C) PRE-AMPLIFIER: Amplifies load transducer signal.
Houses “I.D. chip” used to verify tool functionality
D) LOAD CELL: Precision strain gage load transducer
Provides press force feedback to servo amplifier
E) HOME POSITION PROXIMITY: Counter-clockwise (return) limit sensor
F) ADVANCED PROXIMITY: Clockwise (advance) limit sensor
G) GEAR HOUSING: Durable gear transmission
H) SPLINE: Ball screw driven press ram
I) MOUNTING FLANGE: See Chapter 2 for size and hole pattern
J) GREASE FITTING: Spline (Rod) lubrication point.
K) LUBE ACCESS POINT: Gear lubrication point (availability and location dependant
on press size)