Manual instruction

30
en
must be disposed of in impermeable
plastic bags conforming with the
valid regulations for the disposal of
such waste.
For maintenance on behalf of the
user, the vacuum cleaner must be
disassembled, cleaned and main-
tained as far as feasible, without caus-
ing a risk for the maintenance
personnel or other persons. Prior to
disassembly, the vacuum cleaner
should be cleaned in order to pre-
vent any risks.
The room/enclosure in which the
vacuum cleaner is disassembled
should be well ventilated. Wear per-
sonal protective equipment during
maintenance. After the maintenance,
the maintenance area should be
cleaned.
Products that have come into contact
with asbestos may not be sent in for
repair. Dispose of products contam-
inated with asbestos according to the
applicable country-specific regula-
tions for such disposal.
The current spare parts list for this
vacuum cleaner can be viewed on
the Internet at www.fein.com.
If required, you can change the
following parts yourself:
Fleece filter bag, flat-fold filter, filter
cartridge, hose, tool sleeve
Fault Finding.
Malfunction Cause Troubleshooting
Vacuum cleaner can-
not be switched on.
Circuit breaker of
power connection has
tripped.
Ensure power supply.
Vacuum cleaner in
remote control opera-
tion.
Set operating-mode
selector switch to “I”.
Reduced vacuuming
capacity.
Vacuum cleaner not fit-
ted correctly.
Mount vacuum cleaner
lid properly and com-
pletely close both fasten-
ers.
Vacuum system clogged. Clean vacuum hose and
extension tubes.
Fleece filter bag full. Replace fleece filter bag.
Flat-fold filter full. Replace flat-fold filter.
Dust escapes during
vacuuming.
Incorrect installation
position of flat-fold filter
Correct installation posi-
tion of flat-fold filter.
No suction capacity
when wet vacuuming.
Container full. Empty container.
Automatic shut-off
does not actuate.
Sensors soiled/dirty. Clean sensors and space
in between with a brush.