Ground terminal
The generator ground terminal is
connected to the frame of the generator, the
metal non-current-carrying parts of the
generator, and the ground terminals of each
receptacle. Before using the ground terminal,
consult a qualified electrician, electrical
inspector or local agency having jurisdiction for
local codes or ordinances that apply to the
intended use of the generator.
F
F
i
i
l
l
l
l
a
a
n
n
d
d
c
c
h
h
e
e
c
c
k
k
o
o
i
i
l
l
l
l
e
e
v
v
e
e
l
l
(
(
q
q
u
u
a
a
n
n
t
t
i
i
t
t
y
y
i
i
s
s
6
6
0
0
0
0
m
m
l
l
)
)
Always check the oil level (with machine in a
level position) before starting and if the
engine unexpectedly stops (fig. 2).
For general use you can use an “all
temperature” oil 10W-30
0ºC SAE#10
0ºC - 25 ºC SAE#20
25ºC -35 ºC SAE#30
35ºC SAE#40
F
F
i
i
l
l
l
l
a
a
n
n
d
d
c
c
h
h
e
e
c
c
k
k
f
f
u
u
e
e
l
l
l
l
e
e
v
v
e
e
l
l
Use unleaded fuel only
Remove any power cords
Turn power switches off
Do not overfill – leave air gap at top of fuel
level
Always screw down fuel cap
Clean up any spilled fuel
Do not smoke while operating the
generator
Always use caution!
S
S
t
t
a
a
r
r
t
t
i
i
n
n
g
g
t
t
h
h
e
e
g
g
e
e
n
n
e
e
r
r
a
a
t
t
o
o
r
r
F
F
i
i
g
g
.
.
1
1
+
+
4
4
+
+
5
5
1. Turn on fuel tap (15).
2. Turn on engine switch (12).
3. Move choke lever (13) to closed position
(to restart a warm engine, leave the choke
lever in open or half-open position).
4. Pull slowly on the starter cord until it
engages, then pull sharply to start the
engine (14).
5. Allow the engine to run until it warms up,
and then move the choke lever to the open
position (13).
U
U
s
s
i
i
n
n
g
g
t
t
h
h
e
e
A
A
C
C
O
O
u
u
t
t
p
p
u
u
t
t
(
(
2
2
3
3
0
0
V
V
)
)
Start the generator.
Plug in the electrical appliance plug.
Press AC current protector downward to
“ON”(7).
The voltmeter (11) displays the voltage on
the AC socket. Normally this should be ±
230 V during use.
S
S
t
t
o
o
p
p
p
p
i
i
n
n
g
g
t
t
h
h
e
e
g
g
e
e
n
n
e
e
r
r
a
a
t
t
o
o
r
r
F
F
i
i
g
g
.
.
1
1
+
+
5
5
1. Unplug all cords (5)
2. Turn engine switch to “OFF” (12)
3. Turn off fuel tap (15)
4
4
.
.
S
S
E
E
R
R
V
V
I
I
C
C
E
E
&
&
M
M
A
A
I
I
N
N
T
T
E
E
N
N
A
A
N
N
C
C
E
E
P
P
E
E
R
R
I
I
O
O
D
D
I
I
C
C
M
M
A
A
I
I
N
N
T
T
E
E
N
N
A
A
N
N
C
C
E
E
Daily (pre-operation check)
Check engine oil level
Check fuel hose for cracks or other
damage. Replace if necessary.
Check exhaust-system for leakage.
Retighten or replace gasket if necessary.
Check choke operation
Check recoil starter operation
1
1
s
s
t
t
M
M
o
o
n
n
t
t
h
h
o
o
r
r
2
2
0
0
h
h
r
r
s
s
Replace engine oil
3
3
M
M
o
o
n
n
t
t
h
h
s
s
o
o
r
r
5
5
0
0
h
h
r
r
s
s
Check condition of spark plug. Adjust gap
and clean. Replace if necessary.
Clean, replace if necessary.
6
6
M
M
o
o
n
n
t
t
h
h
s
s
o
o
r
r
1
1
0
0
0
0
h
h
r
r
s
s
Replace engine oil
Clean fuel tap and fuel tank filter. Replace if
necessary.
Check fittings and fasteners. Replace if
necessary.
1
1
2
2
M
M
o
o
n
n
t
t
h
h
s
s
o
o
r
r
3
3
0
0
0
0
h
h
r
r
s
s
Contact a specialized service centre to
check the valve clearance.