Instruction Manual

5. Commissioning
5−28
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Icon files For representation of the SFC−LACI in the configuration
software:
Normal operating
status
Diagnostic case Special operating
status
File:
sfclacin.dib or
sfclacin.bmp
File:
sfclacid.dib or
sfclacid.bmp
File:
sfclacis.dib or
sfclacis.bmp
Tab.5/2: Symbol files
Install GSD file and symbol files
Depending on the configuration program used, install the
GSD file and the icon files with the aid of the appropriate
menu command or copy the files manually into a particular
directory of your programming device/PC.
5.5.2 I/O configuration
The GSD files support two alternative configurations:
Festo standard handling and positioning profile"
(GSDentry as FHPP Standard"):
8 bytes of I/O data, consistent transmission
Festo handling and positioning profile with parameter
channel" (GSD entry as FHPP Standard + FPC"):
2 x 8 bytes of I/O data, consistent transmission