Instruction Manual

5. Commissioning
5−30
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Insert SFC−LACI as slave
The Hardware Configuration" window graphically represents
the structure of the master system. When the GSD file has
been installed, the SFC−LACI can be selected in the hardware
catalogue. It can be found in the group [PROFIBUS−DP]
[Additional Field Devices] [Drives] [Festo], (see Fig.5/1).
In order to insert the SFC−LACI:
1. Pull
the station type Festo SFC−LACI" (DP−V0 and DP−V1)
or Festo SFC−LACI DP−V0" ( 3 ) from the Hardware
Catalogue onto the PROFIBUS line ( 1 ) of the DP master
system (drag & drop).
2. Enter the PROFIBUS address, which you have set using
the FCT or the control panel, into the Properties
PROFIBUS
interface" dialog and confirm the value with
OK.
3. If necessary, enter other settings in the dialogue window
Properties DP slave" (e.g. the response monitoring,
see section 5.5.5 or the startup parameterising, see
section 5.5.4) and confirm with OK.
The SFC−LACI symbol is displayed on the line of the DP
master system (
2 ).