5. Commissioning
5−38
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
5.6.2 Structure of the cyclic I/O data (FHPP standard)
FHPP standard contains 8 bytes of inputand 8 bytes of
output data:
Data Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Output
data
Bytes 1 and 2 (fixed)
are retained in each
operating mode and
transmit control and
Bytes 3 to 8 depend on the operating mode selected (Direct mode,
Record select) and transmit further control and status bytes as well
as setpoint and actual values:
Record number or tar
g
et
p
osition in the out
p
ut data
Input
data
transmit
control
and
status bytes for en
abling the SFC−LACI
and for setting the
operating modes.
Record
number
or
target
position
in
the
output
data
Feedback of actual position and record number in the input data
Further setpoint and actual values depending on the operating
mode
I/O data: Record selection
Data Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Output
data
CCON CPOS Record
no.
Reserved Reserved
Input
data
SCON SPOS Record
no.
RSB Actual position
I/O data: Direct mode
Data Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Output
data
CCON CPOS CDIR Setpoint
value 1
(velocity)
Setpoint value 2
(position, force/torque,...)
Input
data
SCON SPOS SDIR Actual
value 1
(velocity,
force/
torque,...)
Actual value 2
(actual position)
Further 8 bytes I/O as per FHPP−FPC
In the cyclic data a further 8 bytes input data and 8 bytes
output data are permitted for transferring parameters in
accordance with the FPC protocol (Festo Parameter Channel)
} section B.2.