Instruction Manual

5. Commissioning
5−70
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Stop record with HALT and continue
Setpoint record
number
Output data
Acknowledge start
SPOS.B1 (ACK)
Motion Complete
SPOS.B2 (MC)
Actual record
number
Input data
N 1N N + 1
N 1
N
1
0
1
0
1
0
1
0
1
0
1
0
Axis is moving
SPOS.B4 (MOV)
Halt
CPOS.B0 (HALT)
1
0
Start
CPOS.B1 (START)
1
0
Confirm Halt
SPOS.B0 (HALT)
1
2
1 Record is stopped with HALT, the
actual record number N is retained,
Motion Complete" remains reset.
2 Rising edge at START begins recordN
again, Confirm HALT" is set.
Fig.5/7: Stop sequence diagram with HALT and continue