Instruction Manual

5. Commissioning
5−87
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
Parameter / Description CIFCTPNU
Out1: Value for setting condition
The saved value that when reached means that the comparison condition
is considered fulfilled in accordance with 2421/02h.
With record number comparison: bit number Z record number:
bit 1 = record 1 (bit0: do not use).
Example: 0x6 = in record1 and also in record2, the condition is
considered fulfilled and the output is set.
1243 x 2421/04h
Out1: Value for resetting condition
As above, but in accordance with 2421/03h for the resetting condition.
1244 x 2421/05h
Out1: Setting condition rising/falling
Value = 0: The output is set if the reference value accrued from lower
values has been reached in accordance with 2421/04h.
Value = 1: The output is set if the reference value accrued from higher
values has been reached in accordance with 2421/04h.
1245 x 2421/06h
Out1: Resetting condition rising/falling
Value = 0: The output is reset if the reference value accrued from lower
values has been reached in accordance with 2421/05h.
Value = 1: The output is reset if the reference value accrued from higher
values has been reached in accordance with 2421/05h.
1246 x 2421/07h
Out1: Delay
Delay time in [ms] after a resetting condition has occurred. The output is
not reset until the delay time has expired (= switch−off delay).
1247 x 2421/08h
Out1: Inverted
0 = not inverted
1 = inverted
This setting is not taken into account when the output is used for a
brake/clamping unit (see 2421/01h).
1248 x 2421/09h