Instruction Manual

5. Commissioning
5−88
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Parameter / Description CIFCTPNU
Out2: Use
Value Out2 is used as:
0No function
1 Brake output (see section 5.7.11)
2 Digital signal display (see FCT)
3 Output/Compare" (see FCT)
1250 x 2422/01h
Out2: Setting condition
Value The output is set dependent upon:
1 Position comparison
2 Force comparison
3 Speed comparison
4 Record number comparison
10h Ready
11h Motion complete
12h Error
13h Sample in
14h (reserved)
15h ON (during setting of this bit, the output is set immediately)
1251 x 2422/02h
Out2: Resetting condition (delay: see 2422/08h)
Value The output is reset dependent upon:
1 Position comparison + delay
2 Force comparison + delay
3 Speed comparison + delay
4 Record number comparison + delay
10h Ready + delay
11h Motion complete + delay
12h Error + delay
13h Sample in + delay
14h Delay
15h OFF (during setting of this bit, the output is reset immediately)
1252 x 2422/03h
Out2: Value for setting condition
The saved value that when reached means that the comparison condition
is considered fulfilled in accordance with 2422/02h.
With record number comparison: bit number Z record number:
bit 1 = record 1 (bit0: do not use).
Example: 0x6 = in record1 and also in record2, the condition is
considered fulfilled and the output is set.
1253 x 2422/04h
Out2: Value for resetting condition
As above, but in accordance with 2422/03h for the resetting condition.
1254 x 2422/05h