Instruction Manual

5. Commissioning
5−95
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
5.8 Notes on operation
Warning
Danger of injury.
Electric axes can move suddenly with high force and at
high speed. Collisions can lead to serious injury to human
beings and damage to components.
· Make sure that nobody can reach into the operating
range of the axes or other connected actuators (e.g.with
a protective grille) and that no objects lie in the
positioning range while the system is still connected to a
power supply.
Caution
Not using the parametrising interface as designated
causes injury to people and material damage
The parametrising interface (RS232) is
not electrically isolated and
not real−time capable.
It is not intended for permanent connection to PC systems
or as a controller interface.
Controlling the SFC−LACI via RS232 requires, among other
things, a risk assessment by
the user, ambient conditions
free of interference and reliability of data transmission e.g.
via the control program of the higher−order control system.
· Note that control of the SFC−LACI via the RS232 does not
comply with designated use.
· Use the connection only for parameterising, commis
sioning and diagnosis.