Instruction Manual

6. Diagnosis and fault display
6−3
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
6.1 Diagnostics options
Overview organised according to the type of diagnostic
information
Type of diagnostic
information
Access via ... See ...
General status display LEDs on the SFC−LACI Section 6.2
FCT: virtual LEDs in the Device status" window Help for PlugIn
FHPP status bytes SCON and SPOS Section 5.6.2
The current error message
in plain text
Control panel of the SFC−LACI (only type ...−H2) Section 6.3
in plain text
FCT: text field in the Device status" window Help for PlugIn
Diagnostic memory:
the last 16messages
FCT: in the Diagnosis" window
(with existing device connection)
Help for PlugIn
FPC: the second 8 bytes of the cyclic field bus
communication can transfer the contents of the
diagnostic memory
Sections B.2.1
and 6.4
Device−related diagnosis
as per IEC 61158−6 type 3
Diagnosis via the GetDiag" PROFIBUS DP service Section 6.5
Parameterising Control panel: in the [Diagnosis] menu Section 4.3
FCT Help for PlugIn
Tab.6/1: Diagnostic information according to type