Instruction Manual

6. Diagnosis and fault display
6−4
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Overview organised according to the type of access to the
diagnostic information
Access
Brief description Advantages/
features
Detailed
description
LEDs The LEDs indicate the readiness to
operate, positioning status, errors
and bus status.
Fast on−the−spot"
recognition of
errors
Section 6.2
Control panel of an
SFC−LACI−...−H2
On the LCD display:
Messages, warnings and errors
Fast diagnosis
on−the−spot"
diagnosis
Section 6.3
In the [Diagnostic] menu:
Diagnostic data, operating mode,
current positioning record, target and
actual positions, speed as well as
information on communication via
the fieldbus
Detailed
diagnosis
on−the−spot"
diagnosis
Section 4.3
Festo Configuration
Tool
With active device connection:
Display of the current positioning
record, target and actual positions
as well as speed.
Display of the operating mode,
special outputs and operating
states as well as error messages of
the SFC−LACI.
Display of the bus status
Display of the diagnostic memory
Detailed
diagnosis during
commissioning
Help for PlugIn
SFC−LACI
Diagnosing the
PROFIBUS−DP
Standard diagnosis
Device−related diagnosis
Diagnosis via FHPP status bytes
SCON and SPOS
Simple diagnosis
via the field bus
Section 6.5
PROFIBUS via FPC Expanded access to diagnostic
data, e.g.diagnostic memory
Detailed diagnosis
via the field bus
Sections 6.4
and 6.6
Tab.6/2: Diagnostic information as per access