Instruction Manual

6. Diagnosis and fault display
6−15
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
6.5 Diagnosis via PROFIBUS−DP
The SFC−LACI supports the following diagnostic possibilities
via PROFIBUS−DP:
FHPP Status−Bytes (see section 5.6.2):
SCON.B2 WARN Warning
SCON.B3 FAULT Error
SPOS.B5 DEV Drag error
SPOS.B6 STILL Standstill monitoring
Diagnosing the PROFIBUS−DP :
PROFIBUS service GetDiag" with device−related
diagnosis (GbD) when activated.
The alarm model as per DPV1 is not supported.
Structure of the DP diagnosis (GetDiag)
The SFC−LACI supports Device−related" diagnosis of the
GetDiag" PROFIBUS service, as per IEC 61158−6 Type 3.
Note
The Identifier−related" or Channel−related" diagnosis
listed in IEC 61158−6 type 3 is not supported.
The method used for requesting a slave diagnosis can be
found in the manual for the DP master.