Instruction Manual

6. Diagnosis and fault display
6−20
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
6.7 Warning Index pulse warning"
In the homing run to the proximity sensor, the drive initially
moves into the switching range of the sensor and then
reverses. After the switching range is exited, the SFC−LACI
searches for the nearest index pulse. This applies as the
homing point.
Note
Material damage due to moved measuring reference
system
The following situation arises if the switching point of the
proximity sensor and the index pulse lie very close to one
another: Should the switching point move (e.g. due to
temperature influence) such that it then lies behind the
index pulse, then the SFC−LACI will
use the index pulse
after that as a reference point. The entire measuring
reference system would then be offset by 2 mm in
DFME−...−LAS, in DNCE−...−LAS: by 5 mm.
Remedy:
1. Check the distance of the switching point to the index
pulse: See FCT, Homing" page, Homing" register
(or CI 2FFE/0Dh, see appendix B).
2. Then
move the proximity sensor a few tenths of a mm.
1 Switching range
of the proximity
sensor
2 Index pulses
(every 2 or 5mm)
3 Recommended
position: in the
centre between
two index pulses
REF
1
2
3