Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
Data Memory Control
PNU 127 1 ... 2 0 ... 2 uint8 w
Description Commands for EEPROM
Delete EEPROM 127 1 0
Fixed 16 (0x10): Delete data in EEPROM.
Once the object has been written, and after power off/on, the data in the
EEPROM are reset to the factory settings.
Save Data 127 2 1
The data in EEPROM will be overwritten with the current user−specific settings.
Fix 1 (0x01): Save data
Reset Device 127 3 2
0x10: Reset device (EEPROM is not erased, state is identical to that after
switching on/off).
CI 20F1h 01h ... 02h uint8 w
Note
All user−specific settings will be lost on deletion (except for
cycle number). The status after deletion corresponds to
the standard factory setting.
· Always carry out a first commissioning after deleting the
EEPROM.
· When the EEPROM is deleted, the field bus address is
also reset.