Instruction Manual

B. Supplementary information
B−112
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Version FCT PlugIn Min.
CI 2067h 00h Var V−string r
Description Minimum FCT version required
Format = xx.yy" (xx = main version, yy = secondary version)
Version FCT PlugIn Opt.
CI 2068h 00h Var V−string r
Description Optimum FCT version
Format = xx.yy" (xx = main version, yy = secondary version)
Scaling
CI 20D0h 01h, 02h Array uint8 r
Description Units of measurement and decimal places on the control panel.
See CI object 20FFh/PNU 126
Measuring Unit
(unit of
20D0h 01h uint8 r
(unit of
measurement)
Definition of unit of measurement.
The setting for the system of measurement only affects the display.
All parameters are converted to the given unit of measurement only during
writing or reading.
Note:
The SFC−LACI operates internally with metric units; the CI interface with
increments.
Value: Fixed = 1: millimetres, e.g. mm, mm/s, mm/s
2
Scaling Size
(no of places after
20D0h 02h uint8 r
(no. of places after
dec. point)
Number of places after the decimal point.
Fixed = 2