Instruction Manual

3. Installation
3−5
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
If unused plug connectors are touched, there is a danger that
damage may occur to the SFC−LACI or to other parts of the
system as a result of ESD (electrostatic discharge). Place
protective caps on unused terminal connections in order to
prevent such discharges.
Overview of cables and plugs
Connection Cable Type
1 Parameterising interface Programming cable KDI−MC−M8−SUB−9−2,5
2 Controller interface Field bus plug FBS−SUB−9−GS−DP−B
Field bus adapter FBA−2−M12−5POL−RK
3 Voltage supply Power supply cable KPWR−MC−1−SUB−15HC−...
5 Local digital I/Os Connecting cable KM8−M8−... or NEBU−M8−...
6 Motor connection Motor cable NEBM−T1G6−T1G6−...
Encoder cable NEBM−T1G12−T1G12−...
Tab.3/2: Overview of cables and plugs (accessories)
For complying with the IP protection class:
· Tighten the union nuts/locking screws on the plugs by
hand.
· Seal unused M8 connections with type ISK−M8 protective
caps (accessories).
Observe the tightening torques specified in the
documentation for the cables and plugs used.