Instruction Manual

3. Installation
3−7
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
Connection Pin Designation Function Colour
1)
A1 Load voltage +48 VDC load Black, 1
A2 Load voltage GND load Black, 2
1 Logic voltage +24 VDC logic White
2 Logic voltage GND logic Brown
3 Hardware
enable
+24 VDC
hardware enable
Green
4 FE FE
3)
2)
5 Hardware
enable
GND hardware
enable
yellow
Plug housing FE
3)
Earthing strap
with cable lug
M4
Earth
terminal
(housing)
FE
3)
1)
Wire colours of supply cable KPWR−MC−1−SUB−15HC−...
2)
With cable type KPWR−MC−1−SUB−15HC−... not connected.
3)
Use only one connection; see section 3.3
Tab.3/3: Power" connection (voltage supply) on the SFC−LACI
Caution
Damage to the device
The power supply inputs on the SFC−LACI have no special
protection against overvoltage.
· Make sure the permissible voltage tolerance is never
exceeded; see Tab.3/4.