Instruction Manual

3. Installation
3−22
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
3.7.4 Connection by other Sub−D plugs
If plug type FBS−SUB−9−WS−PB−K from Festo or Sub−D plugs of
other manufacturers are used, you must replace the two flat
screws, with which the field bus plug is fastened in the
SFC−LACI, with a bolt type UNC 4−40/M3x5 (included in
delivery).
Note
Note that when using Sub−D plugs from other manufac
turers, only IP20 protection is attained.
Note
If both screws or stud bolts are removed simultaneously,
there is a risk that the plug may be pressed into the
SFC−LACI housing with the internal circuit board.
· Always leave one of the screws or stud bolts fitted while
changing over.
1. First slacken just one of the mounting screws and
removeit.
2. Screw one of the mounting bolts into the vacant tapped
hole and tighten it.
Max. tightening torque: 0.48Nm.
3. Repeat steps 1 and 2 for the other screw.