Instruction Manual

3. Installation
3−26
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
3.9.2 Specifications of the inputs
based on DIN/EN 61131, Part 2 (IEC 1131−2), Type 1
are supplied by the 24−V logic voltage (no electrical
separation).
Note
Damage to the device
The 24 V DC voltage at pin 1 does not have any special
protection against overload.
· Use this connection only for proximity sensors
(sensorsupply).
Use of this connection as a power supply for other devices
is not permitted.
· For connecting the proximity sensor, use a cable with
rotating thread sleeve (union nut) on the end of the cable,
e.g.an extension cable type KM8−M8−... or NEBU−M8−...
· When selecting the proximity sensor, note that the
accuracy of the proximity sensor switching point may
affect the accuracy of the reference point.
· During installation, note the position of the reference
switch relative to the index pulse. If necessary, move the
reference switch (see INDEX PULSE WARNING",
section6.3).