4. Control panel (only type SFC−LACI−...−H2)
4−9
Festo P.BE−GDCP−SFC−LACI−PB−EN en 0812NH
[Diagnostic] [...] Description
[Axis parameter] v max Maximum speed
x neg Stroke limitation: Software end position, negative
x pos Stroke limitation: Software end position, positive
x zp Offset axis zero point
Tool load Tool load (e.g.a gripper on the front plate or on the
piston rod)
[System paramet.] Load Power Load voltage ok?
VDig Digital voltage (= Logic voltage) [V]
I max Max. phase current [A]
P_Pos Average power during last positioning procedure [W]
t_Pos Time taken for the last positioning procedure [s]
Cycle Number of positioning movements
Mode Unit of measurement [mm]
Hom.meth. The parameterised homing method:
RefS.n: Reference switch in negative direction
RefS.p: Reference switch in positive direction
Bl.pos: Fixed stop in positive direction
Bl.neg: Fixed stop in negative direction
LimS.p: Limit switch in positive direction
LimS.n: Limit switch in negative direction
Ref. switch Activated (switching) position of the parameterised
reference switch
Neg. Lim−Sw Activated (switching) position of the negative limit switch
Pos. Lim−Sw Activated (switching) position of the positive limit switch
T_Motor Temperature of the linear motor [°C]
T_LACI Temperature of the SFC−LACI [°C]