5.1.4Simultaneous attempts to access the controller
Caution
Simultaneous or alternating attempts to access the
SFC−LACI via FCT, control panel and controller interface can
cause unpredictable errors.
· Make sure that the FCT, the control panel and the
controller interface of the SFC−LACI are not used at the
same time.
Note
In the following cases, it is not permitted to use the FCT to
access the SFC−LACI for purposes of writing data
(e.g.downloading parameters) or f
or control
(e.g.Move manually" or starting a homing run):
While the SFC−LACI is executing a positioning motion or
when a motion is started during a
ccess (e.g.via the
control interface or via the control panel).
If parameterisation or operation is carried out on the
SFC−LACI with the control panel.
No
te:
· Control by the FCT must not be activated while the drive
is in motion or when control is being carried out via the
field bus.