Festo GDCP−SFCLACIDN−EN en 0812NH
5.1.4Simultaneous attempts to access the controller
Caution
Simultaneous or alternating attempts to access the
SFCLACI via FCT, control panel and controller interface can
cause unpredictable errors.
· Make sure that the FCT, the control panel and the
controller interface of the SFCLACI are not used at the
same time.
Note
In the following cases, it is not permitted to use the FCT to
access the SFCLACI for purposes of writing data
(e.g.downloading parameters) or f
or control
(e.g.Move manually" or starting a homing run):
While the SFCLACI is executing a positioning motion or
when a motion is started during a
ccess (e.g.via the
control interface or via the control panel).
If parameterisation or operation is carried out on the
SFCLACI with the control panel.
No
te:
· Control by the FCT must not be activated while the drive
is in motion or when control is being carried out via the
field bus.