5. Commissioning
527
Festo GDCP−SFCLACIDN−EN en 0812NH
5.4 Commissioning on a DeviceNet master
The following sections detail the configuration and
addressing of the SFCLACI on a DeviceNet interface and a
DeviceNet master. To understand this section, you
should be
familiar with DeviceNet and know the specification.
5.4.1 Overview of commissioning on the field bus
The following steps are required for commissioning the
SFCLACI as a field bus participant:
1. Set the following on the SFCLACI:
Settings
Description
MAC ID Permitted address range: 0 ... 63
Baudrate Permitted: 125 / 250 / 500 kBd
I/O Datalength I/O data length
8 bytes (FHPP standard)
16 bytes (FHPP standard + F HPP−FPC)
· on the control panel (only with type SFCLACI...H2),
see section 4.5.6 and 5.2.1 or
· with the Festo Configuration Tool (see help for the
Festo Configuration Tool).
2. Configure the master (section 5.4.2):
install the EDS file,
or make settings
manually.
3. Test the field bus connection.