5. Commissioning
5−45
Festo GDCP−SFCLACIDN−EN en 0812NH
2.Create readiness to operate Direct mode
Step/
Diti
Control bytes Status bytes
Description
Byte B7 B6 B5 B4 B3 B2 B1 B0 Byte B7 B6 B5 B4 B3 B2 B1 B0
2.1 Basic status
Byte 1 OPM2 OPM1 LOCK RESET BRAKE STOP ENABL Byte 1 OPM2 OPM1 HMI 24VL FAULT WARN OPEN ENABL
2
.
1
Basic
status
(Device control
CCON 0 0 0 0 0 0 0 0 SCON 0 0 0 1 0 0 0 0
(D
ev
i
ce contro
l
HMI = off
)
Byte 2 CLEAR TEACH JOGN JOGP HOM START HALT Byte 2 REF STILL DEV MOV TEACH MC ACK HALT
HMI
=
off)
CPOS x 0 0 0 0 0 0 0 SPOS 0 0 0 0 0 1 0 0
2.2 Disable device
Byte 1 OPM2 OPM1 LOCK RESET BRAKE STOP ENABL Byte 1 OPM2 OPM1 HMI 24VL FAULT WARN OPEN ENABL
2
.
2
Disable
device
control by FCT/HMI
(optional)
CCON x x 1 x x 0 x x SCON x x 0 x x x x x
(
opt
i
ona
l)
Byte 2 CLEAR TEACH JOGN JOGP HOM START HALT Byte 2 REF STILL DEV MOV TEACH MC ACK HALT
CPOS x x x x x x x x SPOS x x x x x x x x
2.3 Enable drive,
Byte 1 OPM2 OPM1 LOCK RESET BRAKE STOP ENABL Byte 1 OPM2 OPM1 HMI 24VL FAULT WARN OPEN ENABL
2
.
3
Enable
drive
,
enable operation
CCON 0 1 x x 0 0 1 1 SCON 0 1 0 1 0 0 1 1
(
Direct mode
)
Byte 2 CLEAR TEACH JOGN JOGP HOM START HALT Byte 2 REF STILL DEV MOV TEACH MC ACK HALT
(Direct
mode)
CPOS x 0 0 0 0 0 0 1 SPOS 0 0 0 0 0 1 0 1
0: 0−signal
1: 1−signal
x: not relevant (optional)
F: Edge positive
Tab.5/5: Control and status bytes Create readiness to operate Direct mode"
Description of 2. Create readiness to operate
2.1 Basic status of the drive when the supply voltage
has
been switched on } Step 2.2 or 2.3
2.2 Optionally: Disable device control via FCT/HMI using
CCON.B5 = 1 (LOCK) } Step 2.3
2.3 Enable drive in Direct
mode
} Homing: Example 4, Tab.5/7
If there are faults after switching on or after setting
CCON.B0(ENAB LE):
} Fault handling: see example 3, Tab.5/6
and
section 6.3 Error messages"