User Manual

Contents and general instructions
XVI
Festo GDCP−SFCLACIDN−EN en 0812NH
Product−specific terms and abbreviations
Term / abbreviation Meaning
0−Signal There is a 0 V signal present at the input or output
(positive logic, corresponds to LOW)
1−Signal There is a 24 V signal present at the input or output
(positive logic, corresponds to HIGH)
Acknowledge Confirm, reply message, e.g.Acknowledge START ."
Acknowledge an error." The user confirms that he has noted the error.
The device then leaves the error status (if the error still exists, it will be
displayed again).
Applied load
(Additional load)
The mass of a workpiece. Applies only to a single positioning record,
seeFig.0/1
AZ (= axis zero point), Axis zero point, see section 1.1.5
EMC Electromagnetic compatibility
FCT (= Festo
Configuration Tool)
Software with uniform project and data management for all supported
device types. The special requirements of a device type are supported
with the necessary descriptions and dialogues by means of plug−ins.
FHPP Festo Handling and Positioning Profile": Uniform field bus data profile
for positioning controllers from Festo. See 1.2.2
FHPP standard FHPP sequence control. See 1.2.2
FPC Festo Parameter Channel" for parameter access. See section 1.2.2
HALT With a HALT signal, a running positioning movement is interrupted and
the drive stops. The positioning record remains active, i.e.with a new
START signal the record will be continued. Compare STOP.
HMI Human Machine Interface" refers to the control panel on the variant
SFCLACI...H2. [HMI = on] means that parameterisation and operation
can begin using the control panel or FCT. The control interface is then
deactivated.
Homing run See overview of measuring reference system in section 1.1.5
I/O Input and/or output
Jog mode Manual positioning in positive or negative direction