User Manual

5. Commissioning
586
Festo GDCP−SFCLACIDN−EN en 0812NH
Example of an automatic brake
1
0
1
0
Drive moves
T Automatic
1
0
1
0
T Switch−off
MC
1
0
1
0
T Switch−on
START
1
0
Controller
energised
Record
completed
1
0
Brake
1
0
T Record
chaining
Start of new
position record
Fig.5/10:Pulse−time diagram automatic brake
In this example, both the time for switching to the next record
and the activation time of th
e automatic brake (T Automatic)
starts to run after the completion of a positioning record
(MC). After the activation time has expired, the brake is
clo
sed and the switch−off time runs simultaneously. After the
switch−off time has expired, the controller end stage is
switched off (less warming).
Aft
er the time for switching to next record has expired, there
is a new internal START signal, the drive, however, does not
start to
move until the switch−on delay has expired.