User Manual
6. Diagnosis and fault display
6−14
Festo GDCP−SFC−LACI−DN−EN en 0812NH
6.4 Diagnostics via field bus
6.4.1 Overview
FHPP status bytes (see section 5.5.2)
SCON.B2 WARN Warning
SCON.B3 FAULT Fault
SPOS.B5 DEV Drag error
SPOS.B6 STILL Standstill monitoring
DeviceNet classes:
DeviceNet class
INST
1)
ATTR PNU
2)
See...
101
(65h)
Diagnosis
memory
Diagnostic event 01h ... 10h 01h 200 Sections
6 4 2
(65h) memory
Fault number 01h ... 10h 02h 201
6.4.2,
B.4.5
Time stamp 01h ... 10h 03h 202
102
(66h)
Diagnostic
memory
administration
Record faults
Resolution
Clear buffer
Number of entries
01h
01h
01h
01h
01h
02h
03h
04h
204 Section
B.4.5
108
(6Ch)
Current faults Device faults 01h 01h 205 Section
B 4 5
(6Ch)
Warnings 01h 02h 215
B.4.5
Extended device faults 01h 0Ah 207
01h 0Bh 208
109
(6Dh)
Field bus
diagnosis
Bus status
Current baud rate
Current MAC ID
Current I/O data length
01h
01h
01h
01h
01h
02h
04h
05h
206 Section
B.4.5
1)
Access via Explicit Messaging
2)
Access via I/O Messaging (FHPP−FPC)
Tab.6/7: Diagnosis via field bus: DeviceNet classes