User Manual

B. Parametrizing via field bus
B−49
Festo GDCP−SFCLACIDN−EN en 0812NH
Fault Number
PNU 201 1 ... 16
d
uint16 r
Description Fault number saved in the diagnostic memory, serves for identifying the fault.
Fault numbers with descriptions: see section 6.3
Event ... 201 ...
See PNU 200
CI 20C9h 01h ... 10h uint16 r
DeviceNet C: 101 A: 2 I: 1 ... 16 uint16 r
Time Stamp
PNU 202 1 ... 16
d
uint32 r
Description Time stamp: Time of the diagnostic event since device was switched on, in the
time unit as per PNU 204/2
Event ... 202 ...
See PNU 200
CI 20CAh 01h ... 10h uint32 r
DeviceNet C: 101 A: 3 I: 1 ... 16 uint32 r
Additional Information
PNU 203 1 ... 16
d
uint32 r
Description Number of movement cycles at the time a fault comes or goes. See PNU 305
Event ... 202 ... ...
See PNU 200
CI 20CBh 01h ... 10h uint32 r
DeviceNet C: 101 A: 4 I: 1 ... 16 uint32 r