B. Parametrizing via field bus
B−84
Festo GDCP−SFCLACIDN−EN en 0812NH
Direct mode: Positioning mode
Direct Mode Base Velocity
PNU 540 uint32 rw
Description Reference value for speed specifications in FHPP direct mode.
The master transmits a percent value, which is multiplied by the base value to
reach to the final setpoint speed.
CI 21F8h 00h uint32 rw
DeviceNet C: 105 A: 40 I: 1 uint32 rw
Direct Mode Acceleration
PNU 541 uint32 rw
Description Acceleration in direct mode in [Inc/s
2
]
CI 20EEh 22h uint32 rw
DeviceNet C: 104 A: 7 I: 34 uint32 rw
Direct Mode Deceleration
PNU 542 uint32 rw
Description Deceleration in direct mode in [Inc/s
2
]
CI 20EFh 22h uint32 rw
DeviceNet C: 104 A: 8 I: 34 uint32 rw
Direct Mode Jerk Acceleration
PNU 543 uint32 rw
Description Jerk when accelerating in direct mode in [Inc/s
3
]
The internal calculation is done with
1
/
10
of the value.
CI 20E7h 22h uint32 rw
DeviceNet C: 104 A: 9 I: 34 uint32 rw