User Manual

B. Parametrizing via field bus
B−108
Festo GDCP−SFCLACIDN−EN en 0812NH
Local Digital Output 1 Trigger OFF
PNU 1242 uint8 rw
Description Out1: Resetting condition. See section 5.6.10
CI 2421h 03h uint8 rw
DeviceNet C: 103 A: 114 I: 1 uint8 rw
Local Digital Output 1 Value ON
PNU 1243 int32 rw
Description Out1: Setting with record number comparison: See section 5.6.10
CI 2421h 04h int32 rw
DeviceNet C: 103 A: 115 I: 1 int32 rw
Local Digital Output 1 Value OFF
PNU 1244 int32 rw
Description Out1: Resetting with record number comparison: See section 5.6.10
CI 2421h 05h int32 rw
DeviceNet C: 103 A: 116 I: 1 int32 rw
Local Digital Output 1 Direction Value ON
PNU 1245 uint8 rw
Description Out1: Edge type for setting condition. See section 5.6.10
CI 2421h 06h uint8 rw
DeviceNet C: 103 A: 117 I: 1 uint8 rw