C.3 Description of additional CI objects
Some objects cannot be accessed via the field bus, but only
via the CI interface. These objects are listed here.
Representation of additional CI objects
Password
CI 20FAh 01h ... 02h Array V−String rw/r
Description Managing the FCT password, entering the super password.
FCT Password
20FAh 01h V−String
Password for the FCT software
Value:<........> (fixed 8 characters, ASCII, 7−bit)
Default: <00000000> (status upon delivery and after resetting)
Super Password
20FAh 02h V−String
Entering the super password.
Resets all passwords (FCT password and HMI password, object 20FB).
Contact Festo Service if you require the super password.
1 Name of the object
2 CI object number
3 Subindices
4 Class
5 Type
6 Description of the object
7 If applicable: description of the
subindices
8 Read/write permission:
r= read only
w= write only
rw = read and write
Fig.C/1:Representation of additional CI objects