C. CI interface
C24
Festo GDCP−SFCLACIDN−EN en 0812NH
Version FCT PlugIn Min
CI 2067h 00h Var V−String r
Description Minimum required FCT PlugIn version
Format = xx.yy" (xx = main version, yy = secondary version)
Version FCT PlugIn Opt
CI 2068h 00h Var V−String r
Description Optimum FCT PlugIn version
Format = xx.yy" (xx = main version, yy = secondary version)
Scaling
CI 20D0h 01h, 02h Array uint8 r
Description Units of measurement and decimal places on the control panel.
See CI object 20FFh/PNU 126
Measuring Unit 01h
Definition of unit of measurement
The setting for the unit of measurement system only affects the display.
All parameters are converted to the given unit of measurement only during
writing or reading.
Note:
The SFCLACI operates internally with metric units; the CI interface with
increments.
Value: fixed = 1: millimetres, e.g.mm, mm/s, mm/s
2
Scaling Size
(no ofplaces after
02h
(no. of places after
dec. point)
Number of places after the decimal point
Fixed = 2