User Manual

3. Installation
3−4
Festo GDCP−SFCLACIDN−EN en 0812NH
1 Parameterising
interface (RS232)
2 Controller interface
3 Power supply
4 Earth terminal
5 Local digital I/Os
6 Motor connection
(e.g.DNCE−...LAS)
1
2
3
45
6
Fig.3/1: Connections to the SFCLACI
Connection to the SFC−LACI−DN
Description
1 Parameterising
interface
M8 socket, 4−pin RS232 interface for parameterising, commissioning and
diagnosis via FCT } section 3.5
2 Controller
interface
Sub−D, 9−pin, plug Interface for connecting to a PLC controller
} section 3.6
3 Voltage supply Sub−D7WT, plug Voltage connection with 2high−current contacts and
5low−current contacts (separate load and logic voltage
supply) } section 3.2
4 Earth terminal Stud bolt, M4 Connection for functional earth } section 3.3
5 Local digital
I/Os
M8 socket, 3−pin Local digital inputs and outputs } section 3.9
6 Motor
connection
Plug connector,
type ITT Cm3
Power supply for linear motor and sensor signals
} section 3.4
Tab.3/1:Overview of connections