User Manual

3. Installation
35
Festo GDCP−SFCLACIDN−EN en 0812NH
If unused plug connectors are touched, there is a danger that
damage may occur to the SFCLACI or to other parts of the
system as a result of ESD
(electrostatic discharge). Place
protective caps on unused terminal connections in order to
prevent such discharges.
Overview of cables and plugs
Connection Cable/plug Type
1 Parameterising interface Programming cable KDI−MC−M8−SUB−92,5
2 Controller interface Field bus plug FBS−SUB−9−BU−2x5POL−B
Field bus adapter FBA2−M125POL
3 Voltage supply Power supply cable KPWR−MC1−SUB−15HC...
5 Local digital I/Os Connecting cable KM8−M8... or NEBU−M8...
6 Motor connection Motor cable NEBM−T1G6−T1G6...
Encoder cable NE BM−T1G12−T1G12...
Tab.3/2:Overview of cables and plugs (accessories)
For complying with the IP protection class: Tighten the union
nuts/locking screws on the plugs by
hand; seal unused M8
connections with type ISK−M8 protective caps (accessories).
Observe the tightening torques specified in the
documentation for the cab
les and plugs used.
Festo plugs which comply with protection class IP20:
screw terminal adapter type FBA1−SL5POL
field bus plug FBS−SUB−9−WS−CO−K.