User Manual

4. Control panel (only type SFCLACI...H2)
4−6
Festo GDCP−SFCLACIDN−EN en 0812NH
4.2 The menu system
Status display and main menu
When the logic voltage is switched on, the SFCLACI carries
out an internal check.
During the first commissioning or when the EEPROM is
deleted, the
error message DeviceNet INIT PARAMETER
ERROR" will appear, as the field bus parameters are not
parameterised (see section 5.2.1).
When the device is swit
ched on again (i.e. when the field bus
parameters have already been completely parameterised
once), the display will show briefly the Festo logo
then change
to the status display.
The status display shows the following information:
The type designation of the SFCLACI
The type of connected drive
The position
of the drive x
a
= ...
(still without significance when unit is switched on)
The current setting of the device control
(HMI = Human Machine Interface)
The main
menu is accessed from the status display using the
<Menu> key. The currently active key function is displayed in
the lower lines of the LCD display.
DeviceNet INIT
PARAMETER ERROR
Diagnostic <menu>
Config <Enter>
SFC–LACI...
D...
Xa = 0.00 mm
HMI:off
<Menu>
} Diagnostic
Positioning
Settings
V ESC <Menu>
<––> OK <Enter>
} HMI control
LCD adjustment
v ESC <Menu>
<––> OK <Enter>