4. Control panel (only type SFCLACI...H2)
4−15
Festo GDCP−SFCLACIDN−EN en 0812NH
4.5.3 [Settings] [Homing paramet.]
Setting the homing method and the speed during reference
travel.
· Observe the instructions in section 5.2.2.
[Homing
paramet.]
Parameter Description
[Homing method] switch negative Homing to the integrated
reference switch at the
retracted end position with
index search
block negative Homing to a negative fixed
stop
block positive Homing to positive fixed
stop
Note: Further homing run methods can only be
configured via FCT.
[Velocity v_rp] v_rp Speed for searching for the
reference point
[Velocity v_zp] v_zp Speed for moving to the
axis zero point
[SAVE...] Save parameters in EEPROM
Note
A new homing run must always be carried out after
modifying the homing run method.
The maximum speed for homing is subject to built−in limits
.