Manual

2. Installation and project overwiev
2−6
Festo P.BE−SFC−DC−PB−S7−EN en 0604NH
Insert SFC−DC as slave
The hardware configuration window represents graphically
the structure of the master system. When the GSD file has
been installed, the SFC−DC can be selected in the hardware
catalogue. It can be found in the group [PROFIBUS−DP]
[Additional Field Devices] [Drives] [Festo], (see Fig.2/1).
In order to insert the SFC−DC:
1. Drag
the station type Festo SFC−DC" or Festo SFC−DC
DP−V0" (3, see section 2.1.1) from the hardware
catalogue onto the PROFIBUS line (1) of the DP master
system (Drag & Drop).
2. Enter the PROFIBUS address, which you have set with the
Festo Configuration Tool or on the control panel in the
dialogue window
Properties PROFIBUS interface..." and
confirm with OK.
3. If necessary, enter other settings in the dialogue window
Properties DP slave" (e.g. the response monitoring or
the startup parametrizing) and confirm with OK.
The icon of the SFC−DC is displayed on the line of the DP
master system (2).