2. TECHNICAL REQUIREMENTS
2.2 Installation cutout features:
panel ready columns
A
Minimum cutout height
2134 mm (84”)
Cutout width
36”: 914 mm (36”)
30”: 762 mm (30”)
24”: 610 mm (24”)
18”: 457 mm (18”)
Minimum cutout depth
610 mm (24”) + panel thickness for flush install
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B
Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
615 (24 ¼”)
565 (22 ¼” )
505 (19 ¾”)
A A
127 mm (5") 127 mm (5")
36":914 (36”)
18": 457 (18”)
24": 610 (24”)
30": 762 (30”)
82 mm
(3 1/2")
min 2134
(84”)
82 mm
(3 1/2")