Submittal Sheet

Page 1 of 2
P/N 780500200 09/18 Rev C
DESCRIPTION
The Field Controls FAD Fresh Air Damper
is a 24VAC power-open, power-close
motorized air damper designed for
installation in a fresh air duct connected
to an outdoor air intake hood and a duct
fan or the HVAC return plenum, to control
the  ow of fresh air into the home. The
FAD is typically controlled by the HHSC or
HHSC+ Ventilation Control as part of the
Healthy Home System™ to meet ASHRAE
62.2 and other fresh air ventilation codes
and standards, but may also be used in a
stand-alone application for either passive
or fan-induced fresh air for ventilation or
makeup air applications.
FEATURES
Power-Open, Power Close
Very low power requirement
Very low air  ow resistance
Stainless steel body and gate
Tear-resistant closed-cell foam rubber seal
tested 500K+ cycles
• Seal ammability meets FMVSS-302
Gas Vent Damper motor and circuit board
certi ed 100K+ cycles
Patented Damper Monitor feature detects
and diagnoses failure (with HHSC+
ventilation control)
Model FAD
FAD Fresh Air Damper
4” – 12” Models
Part No. 46590504, 46590505, 46590506, 46590507, 46590508, 46590510 and 46590512
ENGINEERING DATA
Field Controls LLC reserves the right to modify a product, without prior notice, whether in design, color or speci cations, in order to o er at all times a quality
product that is highly competitive. Please consult your national and local building codes to  nd out whether the installation of electrical products requires the
services of a certi ed technician or electrician. Field Controls and Healthy Home System
TM
are registered Trademarks used under license by Field Controls LLC.
All rights reserved.
Field Controls
2630 Airport Road
Kinston, NC 28504
Customer Service: 252 522-3031
Fax: 1 (800) 367-7942
Visit us at: www. eldcontrols.com
DIMENSIONAL DATA
ITEMS INCLUDED IN KIT
FAD damper, 4” through 12” size
3-wire harness with modular damper connector
• The Fresh Air Ventilation Control™ (FAVC): interactively
works with residential HVAC system thermostat, in
conjunction with the central fan air handler system to
periodically introduce controlled amounts of fresh air
into the home. The FAVC is designed to provide fresh air
ventilation all year long keeping energy conservation,
indoor air quality and comfort in mind.
E-Sensor: plugn play duct-mounted module senses
outdoor temperature and dewpoint, used to inhibit
ventilation during extreme outdoor weather conditions.
Adjustable setpoints for minimum allowable outdoor
temp, max allowable outdoor temp, and max allowable
outdoor dew point (not simply RH). No external
transformer normally required. Interfaces with system
and powered by modular connection in series with
damper cable, includes interface cable.
T-Sensor: same features and platform as E-Sensor, but
with min and max allowable outdoor temperature
setpoints only.
C-Sensor: Current sensor compatible with HHSC+
Auxilliary/makeup air input, used to provide makeup
air by sensing operation of exhausting devices such as
dryers, bath fans and range hoods. Passive device with no
external power requirement.
P-Sensor: Duct-mounted di erential pressure switch
compatible with HHSC+ inputs, similar use as C-Sensor,
adjustable setpoint, may be installed on positive or
negative pressure ducts. May be used as stand-alone
makeup air system sensor.
OPTIONAL ACCESSORIES
780500200 FAD Submittal Sheet Rev C 09-18.indd 1 9/25/2018 3:53:14 PM