User Guide

12
STALE AIR
TO OUTSIDE
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FRESH AIR
TO INSIDE
14
3
/4"
(375)
19"
(483)
*All Duct Connections 6"(150mm)
FILTERS
BLOWERS
*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for servicing unit.
MOTOR
ENTHALPIC CORE
33-5/8"
(850)
BALANCING
DAMPER
BALANCING
DAMPER
CORE
Model FC150ERV
DIMENSIONS FC150ERV inches (mm)
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
All units conform to CSA and UL
standards.
Static Pressure (in w.g.)
Air Flow (cfm)
20
40
60
80
100
120
140
160
180
200
220
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
1 - Low speed
2 - High Speed
2
1
*Sensible Efficiency thermal **Latent Efficiency moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency takes into account all power inputs
Performance
N
et supply air flow in cfm (L/s) against external static pressure
E.S.P
(external static pressure) [cfm (L/s)]
@ 0.1" (25 Pa) 151 (71)
@
0.2" (50 Pa) 140 (66)
@ 0.3" (75 Pa) 131 (62)
@
0.4" (100 Pa) 123 (58)
@ 0.5" (125 Pa) 107 (50)
@ 0.6" (150 Pa) 98 (46)
@ 0.7" (175 Pa) 81 (38)
@0.8 " (200 Pa) 60 (28)
S
ensible Effectiveness
@ 64 cfm (30 L/s) 32°F (0°C) 81%
*
Sensible Efficiency
@
64 cfm (30 L/s) 32°F (0°C) 69%
T
otal Efficiency 50%
@ 64 cfm (30L/s) 95°F (35°C) 47%
VAC @ 60HZ 120
WATTS / Low speed. 63
WATTS / High speed 173
A
mp rating 1.4
LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water vapor
between the two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC
motor. 5 speed fan operation.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
Four threaded inserts at corners of case designed to accept the "S" hooks
and hanging straps supplied with the unit.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion
resistance. Insulated to prevent exterior condensation. Door balancing
ports.
WEIGHT 75 lbs. (34Kg) SHIPPING WEIGHT 77lbs. (35Kg)
ELECTRONICS
Built-in Relay for Interfacing to furnace
OPTIONAL CONTROLS
# DHVC Ventilation Control
2 Speed Fan setting (Low/High) Dehumidistat
#HHSC Healthy Home System Control
Automatically activates the unit to deliver fresh air into your home
#DH1 Dehumidistat
Initiates high speed ventilation when the indoor humidity level exceeds
the set point
OPTIONAL TIMERS
#VTC Ventilation Timer Control - Initiates high speed ventilation
for 20, 40, or 60 minutes, (3 wire) 20 gauge wire (min.) 100'
length
OPTIONAL ACCESSORIES
#WH 186 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh
screen
WARRANTY
Units carry a five (5) year warranty
on the enthalpic (ERV) core and a 5
year replacement parts warranty.