Air Purifying Sstem Installation Guide

Page 2
I. INDICATION FOR USE
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
II. GENERAL INFORMATION
There are different size units available, depending on the square footage of your home. See chart below for
determining your homes needs.
Model
Minimum
Duct
Width
Volts Amps
Hz
Watts
Max Air
Temp °F
Lamp Intensity at 1
meter
Recommended
Max Sq. Feet
UV-12C 9 120 0.5 60 30 190°
37 μW/cm
2
1500
UV-18C 14 120 0.5 60 30 190°
73 μW/cm
2
2000
UV-28C 22 120 1.1 60 60 150°
105 μW/cm
2
3000
UV-28 22 120 1.1 60 60 150°
105 μW/cm
2
3000
UV-12HP 9 240 0.5 60 30 190°
37 μW/cm
2
1500
UV-18HP 14 240 0.5 60 30 190°
73 μW/cm
2
2000
UV-28HP 22 240 1.1 60 60 150°
105 μW/cm
2
3000
UV-12HPC 9 240 0.5 60 60 190°
37 μW/cm
2
1500
UV-18HPC 14 240 0.5 60 30 190°
73 μW/cm
2
2000
UV-28HPC 22 240 1.1 60 30 150°
105 μW/cm
2
3000
The UV-12C,18C,28C,12HPC,18HPC, and 28HPC units are equipped with a circuit board to monitor the operation
of the UV lamp; it indicates the operation of the lamp through an LED indicator light mounted on the cover of the
unit. The circuit board indicates good operation of the lamp by a continuous “GREEN” color on the LED light.
After 8,320 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous
“YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9,000 hours of lamp
operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED
light and the internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. If the
lamp is burned out, the circuit board will indicate this by a continuous “RED” color on the LED and the internal
alarm will beep every 5 minutes.
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power
OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to
direct UVC light from any source.
WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.
WARNING: Designed for a closed duct system. Do not mount near a supply or a return air opening.
WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For
use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed
to be mounted outside on gas fired or heat pump packaged units**.
*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.
**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
r
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
r
hands.