VI. BULB MOUNTING BRACKET SELECTION
The UV-AIRE
TM
units come with an angled mounting bracket and flat mounting bracket to position the bulb either
straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the
configurations chart below when making your selection.
A
NGLED LAMP MOUNTING BRACKET SPECIFICATIONS
Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.
LAMP OFFSET DIMENSIONS
Unit
Min Duct
Size
(inches)
A B
UV-12C 9x12 8-1/2 6-1/2
UV-18C 14x18 13-1/2 10-5/16
UV-28C 22X24 21-3/8 16-1/4
UV-28 22X24 21-3/8 16-1/4
UV-12HP 9x12 8-1/2 6-1/2
UV-18HP 14x18 13-1/2 10-5/16
UV-28HP 22X24 21-3/8 16-1/4
UV-12HPC 9x12 8-1/2 6-1/2
UV-18HPC 14x18 13-1/2 10-5/16
UV-28HPC 22X24 21-3/8 16-1/4
Standard 90°
Installation
(Flat Bracket)
(16” Duct)
Patent Pending
Angled Installation
Single Lamp
(Angled Bracket)
(16” Duct)
UV-Aire™ Configurations
Chart B
Good Best
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
r
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
r
hands.
Exclusive 5 Position Mounting
Straight
Angled Positions