User Manual

Safety Information
Installation
WARNING! To ensure safe and proper operation of your e quipment, it is critical to read and adhere to all of the following
safety warnings and precautions. Improper installation or use of this product can cause damage to the device and
serious bodily injur y or d eath!
1) When using the FRHP32V and FRAP32V with Diesel Exhau st Fluid, mainta ining the purity of the DEF / AUS32
(Aqueous Urea Solution 32.5%) is critical; as such, it is imperative once the system is assembled, it must remain
sealed to ensure the integrity of the fluid. Breaking the seal on the s ystem can lead to fluid contamination.
2) After dispensing DEF be certain to drain all the fluid from the nozzle, making sure it is poi nting downward when
stored. DEF remaining in the nozzle tip and exposed to air will crystal lize and can plug the nozzle.
3) DO NOT
lay the dispensing nozzle on the groun d or any surface that may contaminate the nozzle tip as this can
compromise the purity of the DEF.
4) The base is designed to mount directl y to the barrel bung; as such it has 2” NPS threads. Plumbing sealant
appropriate for the fluids and chemicals being dispense d is highly recommended; the 2” thread ed bung mount does
not require sealant.
5) Storage tanks should be securely anchore d to prevent shifting or tipping when full or empty.
6) If the pump will see periods of low or no use, flush it regularly when pumping DEF, corrosive materials, or fluids that
harden. If the pump is used for DEF, use only DEF or de-ionized water to flush the pump (FRHP32V and F RAP32V
applications).
7) DO NOT use the pump with fluids intended for human consumption.
8) WARNING! This pump is not for use with fluids that hav e a flash point below 100°F (37.8°C, ie: gasoline, alcohol).
Refer to NFPA 325M (Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids) for flash points of
common liquids. Static electricity buildup and discharge co uld result in arc and explosion.
9) On hand operated pumps, leave the handle in the down position when not in use to prevent accidental dispens ing of
fluid.
FR20V and FRHP32V Hand Operated Pumps
Installation
1) Apply thread sealant tape or compound (appropriate for the fluid to b e pu mped) to the suction tube threads; screw tube into
the pump inlet.
2) Slide suction pipe into tank or barrel.
3) Screw pump into tank or barrel application until the spout faces the desired direction for dispensing.
4) Tighten the lock ring secur ely onto the tank or barrel.
5) If applicable, attach dispensing hose to sp out outlet; clamp securely in place.
FRAP32V Air Operated Pump
Installation
1) Apply thread sealant tape or compound (appropriate for the fluid to b e pu mped) to the suction tube threads; screw tube into
the pump inlet.
2) Adjust length of suction tube to desired level.
3) Screw pump into tank or barrel application until the spout faces the desired direction for dispensing.
4) Tighten the lock ring secur ely onto the tank or barrel
5) Attach air supply line to air inlet on pump.
6) Pull up adjusting knob on top of the regul ator.
7) Open air inlet valve to begin flow of fluid; discharge into a suitable container.
8) Adjust air pressure by rotating the knob on top of the regulator until a smooth flow is achieved.
9) Push regulator knob down to lock it into place.
10) Close air inlet valve to stop flow.
11) If applicable, attach dispensin g hose to spout outlet; clamp securely in place.
WARNING!DONOTEXCEED100
p
siAIRPRESSUREONAIRSUPPLYLINE!