Owner's manual

Flow Meter Specifications
Model Nominal Pressure Rating¹ at 100°F (38°C):
Flow Meter ² 400 PSI 28 BAR 2750 kPa
Strainer² 400 PSI 28 BAR 2750 kPa
Air Eliminator 150 PSI 10 BAR 1035 kPa
Solenoid Valve depends upon valve type/model
(1) Pressure rating is reduced at higher operating temperatures.
(2) With optional 150# RF ANSI flanges pressure rating is
285 PSI = 20 BAR = 1965 kPa.
Model Nominal Temperature Rating:
Design temperature: -40°F/+300°F -40°C/+150°C
Pulser ATEX listing : -4°F/+140°F -20°C/+60°C
If the operating temperature can exceed +120°F (+50°C),
use high temperature (HT) rotors, code L (or M).
Model Nominal Capacity on low viscosity liquids (1 cP):
TS10C 40 GPM 150 lpm 9 m³/h
TS15C 60 GPM 230 lpm 14 m³/h
TS20C 150 GPM 570 lpm 34 m³/h
TS30C 250 GPM 10 00 lpm 60 m³/h
 Optimum performance (accuracy & service life) is between
50% and 85% of nominal capacity.
 On low viscosity, lubricating liquids, intermittent service to
125% of nominal capacity is acceptable.
 NTEP approvals are with 5:1 turn-down.
 OIML approvals are with 10:1 turn-down.
 Meters may be used at lower flow rates, but meter error in-
creases below 10% of capacity on low viscosity liquids.
 On higher viscosity liquids, error at low flow rates diminishes
progressively. Over 100 cP performance should be accepta-
ble to 3-5% of capacity, over 1000 cP performance should be
acceptable to 1-2% of capacity.
Liquid Viscosity³:
With standard LV rotors, meters may be used to full nominal
capacity up to 300 cPs (1500 SSU). When viscosity can
exceed 300 cPs (1500 SSU), high viscosity (HV) rotors,
code I (or J) are strongly recommended.
With HV rotors, meters may be used to full nominal capacity
up to 1000 cPs (4700 SSU). In high viscosity service, flow
meter capacity is reduced according to this table:
(3) Teflon bearings are used primarily on shear sensitive
liquids, such as many resins & adhesives.
BL ICM J
cP
11.001.001.001.00 1.00 1.00 32
SSU
10 1.00 1.00 1.00 1.00 1.00 1.00 60
50 1.00 1.00 1.00 1.00 1.00 1.00 240
100 1.00 1.00 1.00 1.00 1.00 1.00 475
200 1.00 1.00 1.00 0.90 0.90 1.00 925
300 0.86 0.86 1.00 0.73 0.73 0.98
400 0.77 0.77 1.00 0.62 0.62 0.96
500 0.71 0.71 1.00 0.57 0.57 0.94
600 0.66 0.66 1.00 0.53 0.53 0.92
700 0.63 0.63 1.00 0.50 0.50 0.90
800 0.60 0.60 1.00 0.48 0.48 0.85
900 0.56 1.00 0.45 0.80
0.54 1.00 0.43 0.75
0.53 0.42
0.41 0.32
0.11 0.09
0.05 0.04
Flow Meter Coefficient
Standard Teflon brgs.
Rotor Code Rot o r Cod e
23,600
Liquid
Viscosity
47,200
4,720,000
472,000
1,000,000
100,000
10,000
1,000
5,000
Liquid
Viscosity
4,725
4,250
3,775
3,300
2,825
2,350
1,875
1,425
Rotors : PPS (polyphenylene sulfide resin),
carbon bearings standard,
Teflon™ bearings optional
Rotor shafts : HC316SS
Internal fasteners : 300 Series SS
Seals : Teflon™ standard,
Meter body & covers:
316 (CF8M) Stainless Steel
Carbon 0.08%
Manganese 1.50%
Phosphorous 0.04%
Sulfur 0.04%
Silicon 1.50%
Chromium 18.0-21.0%
Nickel 9.0-12.0%
Molybdenum 2.0-3.0%
Iron remainder
Shafts for oval gears:
316 Stainless Steel
Carbon 0.10% max.
Manganese 2.0% max.
Silicon 1.0% max.
Chromium 16.0-18.0%
Nickel 10.0-14.0%
Molybdenum 2.0-3.0%
Iron remainder
1 .9