Datasheet
X-2017, www.findernet.com
I
Ordering information
Example: 10 series light dependent relay, 2 NO (DPST-NO) 16A contact, screw terminal connections, 230VAC supply.
1 0 . 3 2 . 8 . 2 3 0 . 0 0 0 0
Series
Type
32 = Double output - 2 NO 16A
41 = Single output - 1 NO 16A
42 = Two independent outputs - 2 NO 16A
51 = Single output - 1 NO 12A
61 = Mounting on street light body - 1 NO 16A
Supply voltage
120 = 120V
230 = 230V
Supply version
8 = AC (50/60Hz)
Technical data
Insulation 10.32 / 41 / 42 10.51 10.61
Dielectric strength between open contacts VAC 1000 1000 1000
Conducted disturbance immunity
Surge (1.2/50μs) on L and N (differential mode)
kV
4 4 6
Other data
Cable grip Ø mm (8.9…12) (7.5…9) —
Screw torque Nm 0.8 0.8 —
Max. wire size solid cable stranded cable solid cable stranded cable —
mm
2
1x6 / 2x4 1x6 / 2x2.5 1x6 / 2x4 1x4 / 2x2.5 —
AWG 1x10 / 2x12 1x10 / 2x14 1x10 / 2x12 1x12 / 2x14 —
Output wires
Material — — Silicone rubber UV resistant
Size mm
2
— — 1.5
Length mm — — 500, ends-ferruled
Rated insulation voltage kV — — 0.6/1
Max temperature °C — — 120
Functions
LED*
10.32 / 10.41 / 10.42 10.51
Supply voltage NO output contact Supply voltage NO output contact
OFF Open OFF or ON Open
ON Open ON Closed
ON
Open
(Timing in Progress)
ON
Open
(Timing in Progress)
ON Closed — —
* The LED is located under the terminal cover, close to the Lux adjustment knob. It indicates the contact status and assists in the
test and setting of the correct light threshold level.
5
10
SERIES
10 SERIES
Light dependent relays 12 - 16A