Data Sheet

XI-2017, www.findernet.com
9
I
12
SERIES
12 SERIES
Time switches 16A
Technical data
Insulation 12.51, 12.61, 12.62, 12.81,
12.A1, 12.A2
12.01, 12.11, 12.31, 12.71
Dielectric strength between supply and contacts VAC 4000 4000
Dielectric strength between open contacts VAC 1000 1000
Rated impulse voltage (between supply and contacts) kV/(1.2/50)μs 6 6
Rated impulse voltage (between open contacts) kV/(1.2/50)μs 1.5 1.5
EMC specifications
Type of test Reference standard
Electrostatic discharge contact discharge EN61000-4-2 4kV 6kV
air discharge EN61000-4-2 8kV 8kV
Radiated electromagnetic field (80…1000MHz) EN61000-4-3 10V/m 10V/m
Fast transients (burst 5/50ns, 5 and 100kHz) EN61000-4-4 4kV 4kV
Voltage pulses on supply
terminals (surge 1.2/50μs)
common mode EN61000-4-5 4kV 2kV
differential mode EN61000-4-5 4kV 2kV
Radiofrequency common mode voltage (0.15…80MHz) EN61000-4-6 10V 10V
Voltage dips 70%U
N
, 40%U
N
EN61000-4-11 10 cycles 10 cycles
Short interruptions EN61000-4-11 10 cycles 10 cycles
Radio frequency conducted emissions 0.15…30MHz EN55014 class B class B
Radiated emissions 30…1000MHz EN55014 class B class B
Terminals
Screw torque Nm 0.8 1.2
Max. wire size mm
2
AWG mm
2
AWG
solid cable 1x6/ 2x4 1x10/ 2x12 1x6/ 2x4 1x10/ 2x12
stranded cable 1x4/ 2x2.5 1x12/ 2x14 1x6/ 2x2.5 1x10/ 2x14
Wire strip length mm 9
Other data
Power back-up (Battery life) 6 years (12.51, 12.61, 12.62, 12.81, 12.A1, 12.A2, 12.71)
Battery type CR2032, 3V, 230mAh (12.51, 12.61, 12.62, 12.81, 12.A1, 12.A2)
Power back-up 100h (12.01, 12.11, 12.31 - following 80h continuous energisation)
Power lost to the environment
12.51, 12.61,
12.81, 12.A1
12.62, 12.A2 12.01, 12.11,
12.31
12.71
in stand-by W 0.2 0.2
without contact current W 0.9 0.9 1.5 2
with rated current W 1.5 2.1 2.5 3 (for 1 pole)
L 12 - Rated current v ambient temperature
1 pole
2 pole