Instructions

13.S2
EN 60669-1/EN 60669-2-1
13.S2.8.230.B000
U
N
230 V AC (50/60 Hz)
U
min
184 V AC
U
max
253 V AC
P 2 VA (50 Hz) / 0.5 W
Ch1
Ch2
2 NO (DPST-NO)
6A 230 V AC
AC1 1380 VA
AC15 (230 V AC) 300 VA
(230 V AC) 200 W
(–10…+50)°C
5 (≤1 mA)
IP20
M
1
FINDER TOOLBOX
2
TP
3
Utility Model - IB13S2VXX - 04/19 - FINDER S.p.A. con unico socio - 10040 ALMESE (TO) - ITALY
13.S2.8.230.B000
CURTAINS ACTUATOR
WIRING DIAGRAM
Channel 1: Ch1 - push button 1 (P1)
Channel 2: Ch2 - push button 2 (P2)
FINDER TOOLBOX APPLICATION
With the Finder Toolbox App you can:
- Set the timings on channels Ch1 - Ch2
- Associate the wireless button
- Set the scenarios
NOTE
- Transmission range: approximately 10 m in free space and without
obstacles
- The transmission range may vary depending on the building structure
Example:
- Reinforced concrete walls and/or metal walls
- Partition walls lled with insulating wool on a metallic backing
- Ceilings with metal or carbon ber panels
- Lead glass or glass with metal cladding, steel furniture
FUNCTIONS
1
2
3
ENGLISH

Summary of content (1 pages)